Wednesday, 18 May 2022 10:21

Yokogawa’s most accurate power analyzer enables precise verification of power losses in transformers

Written by
Rate this item
(0 votes)

Yokogawa today launches the WT5000 Precision Power Analyzer - Transformer Version, which is dedicated to helping transformer manufacturers develop and validate the losses of highly efficient products for utility industry customers.

  • The WT5000 Precision Power Analyzer - Transformer Version offers 0.008% accuracy and achieves the highest possible accuracy at power factors as low as 0.001

Transformers play a crucial role in the power grid. With electricity demand set to soar to as much as 40 TWh by 2040 and with transformers responsible for some 4% of distribution network losses, achieving more efficient transformers has never been more important.

Owners of distribution networks impose penalties on transformer manufacturers according to the degree of losses measured during the no load test. As these penalties can exceed 13,000 EUR per kilowatt and include the measurement uncertainty, it is vital for transformer manufacturers to measure these losses accurately and with minimum uncertainty. This lowers the cost of penalties and builds greater trust with customers.

The WT5000 Precision Power Analyzer - Transformer Version helps manufacturers achieve the highly accurate analysis needed to develop economical and efficient transformers. The instrument is equipped with a special input module that has much better uncertainty specifications for transformer testing.

2022 05 18 102121

The WT5000 Precision Power Analyzer -Transformer Version is Yokogawa’s most accurate power analyzer, offering accuracy of 0.008% at unity power factor and offering the best accuracies at low power factors for commercial frequencies of 45 to 66 Hz. Low power factors have a dramatic effect on accuracy. The instrument offers accuracy of 0.6% of the reading for measurement, even at a power factor as low as 0.001 at 100 V and 1 A.

Kelvin Hagebeuk, Marketing Manager – Test and Measurement, says: “Whether during R&D, production, or acceptance testing, the WT5000 Precision Power Analyzer - Transformer Version produces the reliable measurements that engineers need as they seek to improve transformer efficiencies and verify the losses to reduce the total cost of ownership for utility companies.”

Transformer manufacturers can trust the WT5000 Precision Power Analyzer - Transformer Version’s low power factor abilities, as it is supplied with ISO17025 accredited calibration certificates from Yokogawa’s ISO17025 accredited calibration laboratory. This gives confidence that they comply with the IEC60076-8 standard.

The WT5000 Precision Power Analyzer - Transformer Version is optimized by ISO17025 accredited calibration at 53Hz at power factors of 1, 0.5, 0.05, 0.01 and 0.001. Additional calibration up to 100 kHz ensures performance when measuring distorted waveforms, for example during no-load loss current measurements of transformers. This enables the integrated transformer measurement system to measure power losses with great accuracy and capture any drift outside the limits described in the IEC60076-8 Standard.

Featuring a full touchscreen supported by hardware hotkeys and powerful software for remote data capture, the WT5000 offers a seamless and intuitive experience that makes connecting, configuring, and measuring easier than ever before. The 10.1-inch WXGA touchscreen delivers excellent noise immunity even in high-noise environments.

Using the WT5000 Precision Power Analyzer - Transformer Version, engineers can measure either three or four different power phases at 10 MS/s (18 bits). The high resolution, 10.1-inch WXGA display allows split screen viewing of up to seven waveforms and can display up to 12 pages of measurement parameters, from products as diverse as inverter-driven motors, renewable energy technologies, and traction applications such as pumps, fans, and electric vehicles and power transformers. Measurements can also be displayed in vector format or trending in time.

2022 05 18 102145

Yokogawa also offers supporting software packages that can be used to coordinate several instruments, including the WT5000, into a single measurement suite to view different data sources simultaneously.

Some software features allow users to simultaneously view up to 22 waveforms and two harmonic bar graphs (six waveforms, sixteen trends, two vectors, and three harmonic bar graphs: WTViewerE) in split screen mode. Alternatively, they can zoom in using cursors to see more detail in a particular area of interest. Users can customize, save, and load screen layouts as well as specify the data to be saved in CSV format. The software also allows users to create custom computations, combining values from multiple power analyzers.

Additionally, the software allows users to analyze and control remote measurements in real time or use previously acquired data. In the online mode, users have real-time control of measurements from each connected instrument, allowing them to remotely start or stop integration or collect live measurement values. Users can analyze the latest acquired or previously stored data in the offline mode as well.

Up to 32 GB of internal storage memory can be used to store and recall various custom configurations and test setups. It can also be used to log large amounts of measurement data over long periods of time, behaving just like a logger. This large non-volatile memory makes it easy to store data without preparing any external media.

Using the WT5000’s three-phase delta calculation, engineers can check line voltage and phase voltage simultaneously without changing wiring. The built-in delta computation function allows both star-delta and delta-star conversion, allowing users to calculate individual phase voltages from the line voltages measured in a three-phase, three-wire (3V3A) system.

The WT5000 offers advanced harmonic analysis, allowing engineers to evaluate and compare input and output harmonics of inverters, motors, or power conditioners up to the 500th order.  As well as measuring harmonics and power simultaneously, it also offers side-by-side comparison of harmonics from two different input sources.

In addition to low pass frequency filters and line filters, the WT5000 features advanced filtering capabilities, allowing the analysis of even the most challenging of waveforms with precision.

For further information on the WT5000 Precision Power Analyzer - Transformer Version please click here.

About Yokogawa Test & Measurement

Yokogawa has been developing measurement solutions for 100 years, consistently finding new ways to give R&D teams the tools they need to gain the best insights from their measurement strategies. The company has pioneered accurate power measurement throughout its history, and is the market leader in digital power analysers.

Yokogawa instruments are renowned for maintaining high levels of precision and for continuing to deliver value for far longer than the typical shelf-life of such equipment. Yokogawa believes that precise and effective measurement lies at the heart of successful innovation - and has focused its own R&D on providing the tools that researchers and engineers need to address challenges great and small.

Yokogawa takes pride in its reputation for quality, both in the products it delivers - often adding new features in response to specific client requests - and the level of service and advice provided to clients, helping to devise measurement strategies for even the most challenging environments.

The guaranteed accuracy and precision of Yokogawa's instruments results from the fact that Yokogawa has its own European standards laboratory at its European headquarters in The Netherlands. This facility is the only industrial (i.e. non-government or national) organisation in the world to offer accredited power calibration, at frequencies up to 100 kHz. ISO 17025 accreditation demonstrates the international competence of the laboratory.

- Meet the precision makers at http://tmi.yokogawa.com/eu/

About Yokogawa

Yokogawa provides advanced solutions in the areas of measurement, control, and information to customers across a broad range of industries, including energy, chemicals, materials, pharmaceuticals, and food. Yokogawa addresses customer issues regarding the optimization of production, assets, and the supply chain with the effective application of digital technologies, enabling the transition to autonomous operations.

Founded in Tokyo in 1915, Yokogawa continues to work toward a sustainable society through its 17,500 employees in a global network of 119 companies spanning 61 countries.

For more information, please visit www.yokogawa.com.

Read 974 times